Teledyne Tekmar Fusion UV/Persulfate TOC Analyzer

PN: 14-9600-100

Condition: Used in good working condition.  Last calibrated 9/29/21, PM 1/27/21.  Includes(not pictured) TOC Teklink software on USD drive. 

Description:

The Fusion Total Organic Carbon (TOC) Analyzer utilizes powerful Ultra Violet (UV) Persulfate oxidation allowing superior carbon liberation from even the most challenging matrices. By implementing the patented Static Pressure Concentration (SPC) technology, the Fusion TOC Analyzer is able to achieve unprecedented lowend sensitivity from a Non-Dispersive Infrared (NDIR) detector.

The Fusion TOC Analyzer is designed to offer productivity for a wide variety of applications.

Specs:

Chemistry: Photochemical Oxidation via UV-Persulfate1

Detector: Nondispersive Infrared (NDIR) with Static Pressure Concentration (SPC) - Patented

Analytical Modes: TOC (NPOC), TC- IC, TC, IC

Analytical: Limit of Detection: 0.2 ppb Maximum Measurable Concentration: 4,000 ppm (sample volume and dilution dependent) Carryover: = 1.0% Cross Contamination Precision*: = 1.0% RSD,+/-2 ppb or +/- 0.02 µgC, typical of a mid-range standard (Whichever is greater over seven replicates). * Analytical performance affected by laboratory water, reagent and gas purity, as well as sample container cleanliness, sample matrix, gas regulator cleanliness and precision, and operator skill.

Complete Process and Analysis Time: 4-8 minutes typical for TOC analysis; Typically 12-22 minutes for Triplicate TOC Analysis

Controller: PC, Interface through Windows® 7 Professional or greater

21 CFR Part 11 Software Control: TOC TeklinkTM Software is a 21 CFR Part 11 tool for your laboratory compliance

Data Handling: • Pre-defined Industry Standard Methods and Customized User Defined Methods • Priority samples via schedule interrupt • Real-time and Historical graphical display of NDIR detector data • Reports exportable XML, CSV and HTML format • Recalculation of data, outlier deletions, and precision performance criteria controls • Ability to view historical results from multiple schedules on one graphical display

Calibration: • Auto-Calibration from Single Stock Standards or User Calibration Standards • Multi-point (Linear or Quadratic) and auto-blanking • Ability to use one calibration curve and blank for entire instruments’ analytical range • Auto-Check Standards from Single Stock Standards or User Calibration Standards - Pass / Fail Criteria - Decision Control upon Failure (Halt, Re-Calibrate, or Continue)

Other Features: • Auto-System Suitability with Performance Measurements • Auto-dilution of samples/standards • Validation Support Package Available • Pre-programmed point and click method setup • Programmable flow rate and pressure control and monitoring • Auto-Leak Check • Automatic shutdown/standby • Self-cleaning sample handling process that cleans reactor chambers on every repetition • Intellidilution

Official Methods: EPA 415.1- 415.3, 9060A, Standard Method 5310C, ASTM D4779 and D4839, and prENV 13370, Cleaning Validation / USP TOC Method <643> / EP 2.2.44 / JP

Dimensions: 18 inches (45.7 cm) W x 24.5 inches (62.2 cm) D x 32 inches (81.3 cm) H

Carrier Gas Supply: 99.99% pure nitrogen cylinder or 99.9% pure nitrogen generator

Inlet Carrier Gas Pressure: 65 to 100 psi

WORLDWIDE SHIPPING AVAILABLE

 